PTB >> New Products - January 2012
2011 Products of the Year
Customers can choose between a portable configuration and an automated system, which can be operated with all common industrial robots. CoreView version 5.0 software has been configured to achieve improved utilization of the operating system, memory management, and 3rd-party 64-bit software. The products include Blue Light LED technology, which enables a greater variety of surface finishes to be measured or reverse engineered. For Free Info Visit http://info.hotims.com/40429-245
The single-emitter, diode-based design system operates on familiar Hypertherm control platforms, with pre-developed cutting processes that simplify table integration and operation. The power supply is smaller than CO2 laser systems, and the fiber laser delivery enables the beam to travel greater distances, allowing for installation on larger tables. For Free Info Visit http://info.ims.ca/40429-246
It incorporates a single 12-bit monochrome camera that can easily switch to color imaging. The BZ-9000 incorporates a Z-stack and image stitching function that allows users to stitch up to 1,200 images in XY directions. The BIOREVO also provides options for quantitative analysis, including standard two-dimensional measurements, cell counting, and brightness analysis. A Real-Time 3D Module generates a three-dimensional image of a fluorescent specimen. For Free Info Visit http://info.hotims.com/40429-247 New Products
The 3D capability of the LD8900 makes it possible to measure radially symmetric divergences or angularly different types. The LD8900 has a dynamic range of >24dB, while the LD8900R has a dynamic range of >36dB, providing greater detail in the “tails” of the far-field pattern. The LDR8900R also offers real-time measurements of Mode Field Diameter (MFD) in single-mode optical fibers; its angular field of view is 144° with a resolution of 0.055°. In addition to measuring diffusion materials, the LD8900 can be used to optimize gradient index (GRIN) lenses and measure laser diodes at any stage in their manufacture. For Free Info Visit http://info.hotims.com/40429-205
The camera provides thermal video through darkness, light fog, or smoke. The EyeSec line features IP or analog communication options with 320 x 240 25μ or 640 x 480 17μ resolution. The DualSec dual-video (thermal and visual) channel pan tilt camera system allows mediumrange observation and detection. The RangeSec imager, a high-sensitivity, cooled midwave (3-5 μm) thermal camera, utilizes a 19mm to 275mm continuous zoom (29° to 2° field-ofview) or a 47.5mm to 687mm continuous zoom lens (12° to 0.8° field-of-view). For Free Info Visit http://info.hotims.com/40429-206 Color Sensors The TCS3x72 Series is the industry’s first color sensor with an IR blocking filter integrated directly on-chip and localized only to the color sensor photodiodes. In addition, the on-chip IR blocking filter enables the devices to perform ambient light sensing (ALS). For color sensing in closed environments with no IR light sources, the TCS3x71 Series applications include closed-loop color temperature feedback control in solid-state lighting (SSL) and LED RGB backlit displays. For Free Info Visit: http://info.hotims.com/40429-207 Laser Diode Module The module meets OEM analytical and general scientific laser application needs, including laser-induced fluorescence, microscopy, spectroscopy, lithography, data storage, flow cytometry, cancer detection, remote optical sensing, holography, and illumination. For Free Info Visit: http://info.hotims.com/40429-208
Pulsewidths vary from 600ns to CW, with power capabilities up to 125W with adequate cooling. The 784 is manufactured as a RoHS-compliant assembly, but military versions are also available. For Free Info Visit: http://info.hotims.com/40429-209 Industrial Sensors The 18mm devices have sensing distances ranging from 70mm to eight meters. All models feature M12 quick-disconnects and are available in NPN and PNP output logic configurations. For Free Info Visit http://info.hotims.com/40429-210
The product offers a non-critical 1-to-1 mix ratio by weight or volume, and a low mixed viscosity of 1,400 to 1,500 cps. Additionally, users can work with a 100 gram mass of the adhesive at room temperature for up to 90 minutes. EP37-3FLF has a bond shear strength exceeding 2,000 psi and a T-peel strength of 25 pli. The flexible epoxy has an elongation of 180% and superior electrical insulation properties with a volume resistivity of 1x1014 ohm-cm. It bonds to substrates including metals, glass, ceramics, rubbers, and many plastics. For Free Info Visit: http://info.hotims.com/40429-211 The microscope offers accurate and rapid analysis of trace evidence, including glass, paints, fibers, and documents. For Free Info Visit http://info.hotims.com/40429-214
The instruments readily achieve 10E-6 torr vacuum during operation with elastomer (Viton™ or Buna-N) seals. The McPherson models have master polished optics, multiple entrance and exit port locations, and high precision wavelength drives for wavelength reproducibility. Specialized high reflectivity coatings provide up to 78% reflective efficiency at wavelengths as short as 120 nm. The device has an f/4.7 aperture ratio (670mm f.l.). The tools are available in focal lengths of 0.67, 1.0, 1.3, and 2-meters. For Free Info Visit http://info.hotims.com/40429-212
The instrument provides source and measurement unit capabilities at 20V and 1A signal levels. In a single enclosure, the Model 2401 integrates a highly stable DC power source with an instrument-grade 51⁄2 or 61⁄2-digit multimeter. For Free Info Visit http://info.hotims.com/40429-213
In addition to careful control of the grinding and polishing of these complex lenses, Bern Optics verifies the centration of each element before and after cementing. They can be produced with or without specialized coatings to meet specific requirements. For Free Info Visit http://info.hotims.com/40429-215
With a single-point spectrometer, users can analyze spectral differences from sample to sample and then, by selecting discrete filters in and around spectral areas with the most significant differences, use SpectroCam to create an image that shows vivid contrast between the samples. The SpectroCam has a wideband CCD that is responsive from the visible through near-infrared spectrum. Image speed is 20 fps at full resolution, and the standard F-Mount configuration accommodates a range of lens choices, focal lengths, and fields of view. Each system includes a lens, eight standard interchangeable filters, and software. For Free Info Visit http://info.hotims.com/40429-216
Blue laser diodes can also be operated with iC-NZN. The maximum available laser diode current is 300mA, and the devices have an adjustable current limit. When the current limit is reached, it is signaled as an error message output which also indicates undervoltage and overtemperature. There is a safety shutdown function for the output stage in the event of overtemperature. The device can also be driven by either LVDS or TTL pulse signals. iC-NZN and iC-NZP have a standby mode with a low current consumption of < 50 μA. For Free Info Visit http://info.hotims.com/40429-217
A camera mount incorporates topside and back focus adjustment. A changeable rear cell enables the Z10-HDCF to be simply adapted for use on camera formats between 1/3- and 2/3-inch including 3CCD formats. For Free Info Visit http://info.hotims.com/40429-219
The SPD_B includes a Geiger-mode InGaAs avalanche photodiode and thermoelectric coolers that ensure high detection efficiency up to 30%, a very low dark count rate of < 5.10-6 per ns gate, and a low timing jitter of < 180ps. The SPD_B comes with a graphical user interface compatible with LabView and C++. For Free Info Visit http://info.hotims.com/40429-220
Apertures are integrated into the package to reduce crosstalk. The SFH 7773 detects objects up to a distance of 15cm (5.9 in.) while simultaneously measuring the intensity of the ambient light. Its power consumption is a maximum of 5μA in standby mode and 300μA in operational mode. The integration time of the detector and, thus, the detection range of the proximity sensor, can be selected via the I2C interface. The 5.3mm x 2.5mm x 1.2mm sensor can also be adjusted to the transparency of the smart phone cover. A variety of sensitivity levels is available, ranging from 3 to approximately 65.500 lux and 0.03 to 655 lux. For Free Info Visit http://info.hotims.com/40429-218
Photonics West PREVIEW
Available in thicknesses of 0.5 to 3 mm, our HIE glass has improved scratch & impact resistance, improved resistance to temperature fluctuations and improved flexibility strength. This thin yet strong glass can be custom fabricated & various coatings applied to provide a fully integrated optics solution. www.abrisatechnologies.com
Applications range from noisy industrial environments to sensitive high voltage applications where system isolation is necessary. Features: 10kVrwm; .51 Gain (typical); Optically clear encapsulation. www.voltagemultipliers.com/html/ Opto-coupler%20Information%20Index.html
The device has been specially designed for achieving low dark count and afterpulsing rates in free-running mode. The module can operate at two detection probability and with an adjustable deadtime. www.idquantique.com/scientific-instrumentation/products-overview.html
These stages offer unobstructed motion and ±10° of angular rotation. Phone: (800)360-4598; Fax: (603) 893-7857; sales@nationalaperture.com www.naimotion.com The new ray path sorting feature lists and displays every possible ray path in your design both quantitatively and visually. www.lambdares.com
We specialize in fabricating customized process sequences for many application areas including optics and photonics. Inquire about Gradient-index (GRIN) lens fabrication capabilities! www.mems-exchange.org
FRED's ability to propagate both incoherent and coherent light applies to a diverse range of applications that include stray light analysis, laser applications, illumination, imaging systems and much more! www.photonengr.com
Labsphere specializes in the design and manufacture of high end light measurement solutions for the LED/SSL lighting industry, uniform sources for remote sensing and imager calibration, optical coatings and materials, and instrumentation and reflectance standards for spectroscopy applications. www.labsphere.com
Standard features include touch-screen remote, fully motorized controls and Smart Zoom™ for repeatable lateral resolution at all zoom settings. Options include wavelengths from 532nm- 1053nm, a range of apertures and mounting configurations, and Dynamic Interferometry® capability to measure despite vibration and turbulence. www.4dtechnology.com/products/accufiz.php In addition, the fully integrated Glass Expert tool automatically finds the optimal set of glasses for any lens design, in a fraction of the time required by manual glass selection. www.opticalres.com/cv/cv104.html
From project initiation, throughout the development process, manufacturing and aftermarket support, our focused approach has been sought by customers for nearly three decades. www.OEMImaging.com Photonics West Booth # 5207
Connector air-polishing for fiber denub and epoxy removal, traditionally performed manually, is now integrated in Rev. Additionally, bare fibers can be polished without damage or breakage. www.krelltech.com
Gold and silver platings are among the finish offerings and all products are precision cleaned, nitrogen purged and vacuum sealed in class 100 packaging. www.uccomponents.com/default.asp?pg=printcatalog
Laser heating is used rather than electrodes or a filament to ensure repeatable performance and low maintenance. www.AFLglobal.com
Advanced safety features include current limits, slow start, and ESD protection. Ideal for applications where stability is critical and space is tight. PLD available up to 6.5 A. PTC available up to 10 A. www.teamwavelength.com/ptb1
|
||